Experimental techniques and safety
In a minute
Good practical chemistry means working safely, reading each instrument to the right precision, and knowing why each standard technique is used. This lesson covers all three, from making a to .
You'll be able to
- Identify the hazards in an investigation and address its safety, ethical and environmental issues.
- Choose and read the right instrument for mass, volume, time, temperature, length, , current and potential difference.
- Describe how to make standard solutions and , dry a solid to constant mass, carry out and , and set up electrochemical cells.
- Outline how to separate a , and the purpose of , , , , melting points, colorimetry and molecular modelling.
Before you start3 quick questions on what this builds on
Revise first: 1.1 The particulate nature of matter, 1.6 The mole and molar mass, 1.8 Concentration and Avogadro's law, 2.7 Chromatography, 4.1 Measuring enthalpy changes, 6.2 The pH scale and Kw, 6.3 Strong and weak acids, neutralization and pH curves and 6.12 Oxidation and reduction of organic compounds
Safety, ethics and the environment
A risk assessment lists each hazard, judges its risk and gives a control measure that reduces it. Hazard pictograms and the supplier's safety data sheet show what each substance can do.
Match the control to the hazard. Use a fume cupboard for toxic gases and vapours. Heat flammable liquids with a water bath, never a naked flame. For corrosive substances, wear eye protection and use the most dilute solution that works.
To protect the environment, use small quantities and less hazardous reagents. Collect heavy-metal and organic waste in labelled containers; never pour it down the sink.
Ethical issues are about honesty. Report all your data, including results that don't fit. Credit your sources, and get consent if people are involved.
Try it first, then reveal one step at a time.
- Name each hazard: a flammable liquid and a harmful vapour.
- Flammable: remove the ignition source, so heat with a water bath.
- Harmful vapour: a fume cupboard draws it away from you.
- Heat the cyclohexane in a water bath, not over a Bunsen flame, because its vapour could catch fire from a naked flame. Work in a fume cupboard, because the vapour is harmful if breathed in.
Try it first, then reveal one step at a time.
- Be specific about the harm: "it pollutes water" is too vague.
- Lead is a toxic heavy metal that is not broken down, so it builds up along food chains.
- Then give the safe route: a labelled waste container.
- Lead(II) ions are toxic to aquatic life and to people. Lead is not broken down, so it builds up along food chains. Collect the solution in a labelled heavy-metal waste container.
Measuring to the right precision
Record each reading to the instrument's precision, with its unit: every digit of a digital display, or to the nearest half division of a scale you read by eye. Keep trailing zeros: a balance showing is recorded as . Uncertainties follow in 7.2.
For mass, zero (tare) the balance first. To transfer a solid, weigh by difference: weigh the container with the solid, tip the solid out, and weigh the container again.
For volume, pipettes and volumetric flasks give one fixed volume very precisely. A burette gives any volume; a burette marked every is read to . Measuring cylinders are quick but much less precise.
Read each scale at the bottom of the meniscus (the curved liquid surface), with your eye level with it. Reading from above or below gives a parallax error. For a dark solution, such as manganate(VII), read the top instead.
For time, a stopwatch shows , but when timing by hand, your reaction time of a few tenths of a second is the real limit.
For temperature, read a thermometer to half its smallest division, or use a digital probe. Keep the bulb in the liquid, stir, and wait for a steady reading.
For length, a ruler reads to the nearest millimetre.
For pH, universal indicator gives only a rough value. A pH meter is more precise, and accurate once calibrated with buffer solutions of known pH.
For current, an ammeter goes in series. A voltmeter goes in parallel, across the cell. Its high resistance means it draws almost no current.
Try it first, then reveal one step at a time.
- Titre = final reading initial reading = .
- Keep two decimal places: write , not .
Try it first, then reveal one step at a time.
- A meter must be checked against known values before you trust it.
- Rinse the electrode between solutions, and wait for the reading to settle.
- Calibrate the pH meter using buffer solutions of known pH. Rinse the electrode with deionized water before placing it in the lemon juice. Wait until the reading is steady before recording it. Record the temperature too, because pH depends on temperature.
Solutions, titrations and cells
A has an accurately known concentration (1.8).
For a , pipette a known volume of stock solution into a volumetric flask and make it up to the mark. The amount of solute is unchanged, so .
Drying to constant mass makes sure all the water is gone. Heat, cool in a desiccator (so the solid can't reabsorb water), and weigh. Repeat until two successive masses agree within the balance's precision.
In a , one solution is added from a burette to a pipetted volume of another. Do a rough titre, then accurate ones, adding dropwise near the and swirling over a white tile.
Repeat until you have concordant titres, within of each other, and average only those.
Acid–base titrations use an indicator, or a pH probe. Redox titrations may not need one: purple manganate(VII), , added from the burette is decolourized as it reacts, so the first lasting pale pink marks the end point.
In , a reaction changes the temperature of a known mass of water or solution, in an insulated, lidded cup or, for a fuel, a can above the flame. then uses the of water (4.1).
A voltaic cell has two half-cells joined by a wire and a salt bridge. Clean the metal electrodes with sandpaper and use a high-resistance voltmeter. An electrolytic cell needs a DC power supply, often with an ammeter in series.
Try it first, then reveal one step at a time.
- Amount needed: .
- The crystals contain water, so use the hydrate's molar mass. With values from the data booklet (section 7), .
- .
- The anhydrous molar mass, , would give : too little solute.
Try it first, then reveal one step at a time.
- Every step must keep all the solute and give exactly .
- Name the water (deionized or distilled) and the glassware (a volumetric flask).
- Dissolve the crystals in a little deionized water in a beaker. Transfer the solution to a volumetric flask. Rinse the beaker and stirring rod with deionized water into the flask so no solute is lost. Add deionized water until the bottom of the meniscus is on the mark. Stopper the flask and invert it several times to mix.
Separating, purifying and identifying
To separate a , use a property its parts don't share. Filtration removes an insoluble solid from a liquid; evaporation recovers a dissolved solid.
separates liquids with different boiling points, or a solvent from a solution. The vapour condenses in a sloping condenser and is collected.
heats a reaction for a long time. The condenser stands upright, so volatile substances condense and drip back instead of escaping (6.12).
Paper or thin-layer separates and identifies components. Spot the sample on a pencil baseline above the solvent, and cover the container. Compare each , , with known substances run in the same conditions.
purifies a solid. Choose a solvent that dissolves it well when hot but poorly when cold. Dissolve it in the minimum of hot solvent, and let it cool slowly. The product crystallizes while soluble impurities stay dissolved. Filter, wash with a little cold solvent, and dry.
Melting point determination tests purity. A pure solid melts sharply at its data value. Impurities lower the melting point and widen the range.
Use light of the colour the solution absorbs most, such as orange-red light for a blue solution. Zero the instrument with a blank of solvent, measure the standards, then the sample. A spectrophotometer does the same at one exact wavelength.
Molecular modelling, with ball-and-stick kits or software, shows molecules in three dimensions. Use it to see shapes and bond angles and to compare isomers.
Try it first, then reveal one step at a time.
- Compare the measured melting point with the data value.
- Give what a pure solid does, then both effects of impurities.
- Measure the melting point and compare it with the literature value. A pure solid melts sharply, over a narrow range, at that value. Impurities lower the melting point and make the solid melt over a wider range. So a sharp melting point matching the literature value suggests the product is pure.
Try it first, then reveal one step at a time.
- Diluted solution: .
- The bath liquid was diluted from to , a factor of 10, so multiply by 10.
- . Diluting first keeps the absorbance within the range of the standards.
Common mistakes
- Writing just "water" in a method. Tap water adds ions, so say deionized or distilled water.
- Giving a burette or pipette only a water rinse before filling it. Water left inside dilutes the solution, so finish by rinsing each with the solution it will hold.
- Vague environmental answers such as "it pollutes water". Name the specific harm.
- Saying impurities raise the melting point. They lower it and widen the melting range.
- Using the anhydrous molar mass for a hydrated solid. Include the water of crystallization in .
Exam tips
- "Suggest" a precaution: name the specific hazard and the measure that controls it, such as a fume cupboard for a toxic gas. "Wear goggles" alone is too general.
- "Outline" a method: give the steps in order, name the apparatus (volumetric flask, pipette, burette) and the key detail, such as making up to the mark with deionized water.
- Record each reading to the instrument's precision, with its unit. Trailing zeros count: from a pipette, not .
Key takeaways
Practise this
51 past-paper questions on Experimental design, safety and evaluation in the Chemistry HL bank, each with a mark scheme and a worked explanation.
Also: Analytical techniques (49)