Good practical chemistry means working safely, reading each instrument to the right precision, and knowing why each standard technique is used. This lesson covers all three, from making a to .

You'll be able to

  • Identify the hazards in an investigation and address its safety, ethical and environmental issues.
  • Choose and read the right instrument for mass, volume, time, temperature, length, , current and potential difference.
  • Describe how to make standard solutions and , dry a solid to constant mass, carry out and , and set up electrochemical cells.
  • Outline how to separate a , and the purpose of , , , , melting points, colorimetry and molecular modelling.
Before you start3 quick questions on what this builds on
Check yourself
How many of solute are in 20.0 cm3\pu{20.0 cm3} of a 0.150 mol dm−3\pu{0.150 mol dm-3} solution? Give 3 significant figures.
Check yourself
In paper chromatography, what is the ?
Check yourself
Sodium hydroxide solution is added from a burette to hydrochloric acid containing phenolphthalein. What colour change marks the ?

Revise first: 1.1 The particulate nature of matter, 1.6 The mole and molar mass, 1.8 Concentration and Avogadro's law, 2.7 Chromatography, 4.1 Measuring enthalpy changes, 6.2 The pH scale and Kw, 6.3 Strong and weak acids, neutralization and pH curves and 6.12 Oxidation and reduction of organic compounds

Safety, ethics and the environment

A risk assessment lists each hazard, judges its risk and gives a control measure that reduces it. Hazard pictograms and the supplier's safety data sheet show what each substance can do.

Match the control to the hazard. Use a fume cupboard for toxic gases and vapours. Heat flammable liquids with a water bath, never a naked flame. For corrosive substances, wear eye protection and use the most dilute solution that works.

To protect the environment, use small quantities and less hazardous reagents. Collect heavy-metal and organic waste in labelled containers; never pour it down the sink.

Ethical issues are about honesty. Report all your data, including results that don't fit. Credit your sources, and get consent if people are involved.

Worked exampleA student dissolves a solid in hot cyclohexane, which is highly flammable and gives off a harmful vapour. Suggest two precautions, each with a reason.

Try it first, then reveal one step at a time.

  1. Name each hazard: a flammable liquid and a harmful vapour.
Worked exampleAfter an experiment, a student has some solution containing lead(II) ions, PbX2+(aq)\ce{Pb^2+(aq)}. Outline why it must not go down the sink, and state how it should be disposed of.

Try it first, then reveal one step at a time.

  1. Be specific about the harm: "it pollutes water" is too vague.
Check yourself
A reaction gives off chlorine, a toxic gas. Which control measure deals with this hazard?
Check yourself
Which of these is an ethical issue, rather than a safety or environmental one?

Measuring to the right precision

Record each reading to the instrument's precision, with its unit: every digit of a digital display, or to the nearest half division of a scale you read by eye. Keep trailing zeros: a balance showing 2.50 g\pu{2.50 g} is recorded as 2.50 g\pu{2.50 g}. Uncertainties follow in 7.2.

For mass, zero (tare) the balance first. To transfer a solid, weigh by difference: weigh the container with the solid, tip the solid out, and weigh the container again.

For volume, pipettes and volumetric flasks give one fixed volume very precisely. A burette gives any volume; a burette marked every 0.1 cm3\pu{0.1 cm3} is read to 0.05 cm3\pu{0.05 cm3}. Measuring cylinders are quick but much less precise.

Read each scale at the bottom of the meniscus (the curved liquid surface), with your eye level with it. Reading from above or below gives a parallax error. For a dark solution, such as manganate(VII), read the top instead.

Close-up of part of a burette scale from 23.0 at the top to 24.0 at the bottom, with a mark every 0.1 cubic centimetres. The liquid surface curves down in the middle, forming a meniscus. The bottom of the meniscus sits exactly halfway between the 23.4 and 23.5 marks. An eye on the left looks along a dashed horizontal line level with the bottom of the meniscus. The reading is 23.45 cubic centimetres. 23.0 23.4 23.5 24.0 bottom of the meniscus: 23.45 cm³ eye level with the meniscus Burette scales read downwards: the numbers grow towards the tap.
Burette numbers increase downwards. Halfway between two marks is recorded as 23.45 cm3\pu{23.45 cm3}.

For time, a stopwatch shows 0.01 s\pu{0.01 s}, but when timing by hand, your reaction time of a few tenths of a second is the real limit.

For temperature, read a thermometer to half its smallest division, or use a digital probe. Keep the bulb in the liquid, stir, and wait for a steady reading.

For length, a ruler reads to the nearest millimetre.

For pH, universal indicator gives only a rough value. A pH meter is more precise, and accurate once calibrated with buffer solutions of known pH.

For current, an ammeter goes in series. A voltmeter goes in parallel, across the cell. Its high resistance means it draws almost no current.

Worked exampleIn a titration, the burette reads 3.85 cm3\pu{3.85 cm3} at the start and 27.40 cm3\pu{27.40 cm3} at the end. Calculate the titre (the volume added).

Try it first, then reveal one step at a time.

  1. Titre = final reading −- initial reading = 27.40−3.8527.40 - 3.85.
Worked exampleOutline how a student should use a pH meter to measure the pH of a sample of lemon juice accurately.

Try it first, then reveal one step at a time.

  1. A meter must be checked against known values before you trust it.
Check yourself
The bottom of the meniscus in a burette is exactly halfway between the 18.318.3 and 18.418.4 marks. What reading, in cm3\pu{cm3}, should be recorded?
Check yourself
How should a voltmeter be connected to measure the potential difference of a voltaic cell?

Solutions, titrations and cells

A has an accurately known concentration (1.8).

For a , pipette a known volume of stock solution into a volumetric flask and make it up to the mark. The amount of solute is unchanged, so C1V1=C2V2C_1V_1 = C_2V_2.

Drying to constant mass makes sure all the water is gone. Heat, cool in a desiccator (so the solid can't reabsorb water), and weigh. Repeat until two successive masses agree within the balance's precision.

In a , one solution is added from a burette to a pipetted volume of another. Do a rough titre, then accurate ones, adding dropwise near the and swirling over a white tile.

Repeat until you have concordant titres, within 0.10 cm3\pu{0.10 cm3} of each other, and average only those.

Acid–base titrations use an indicator, or a pH probe. Redox titrations may not need one: purple manganate(VII), MnOX4X−\ce{MnO4^-}, added from the burette is decolourized as it reacts, so the first lasting pale pink marks the end point.

In , a reaction changes the temperature of a known mass of water or solution, in an insulated, lidded cup or, for a fuel, a can above the flame. Q=mcΔTQ = mc\Delta T then uses the of water (4.1).

A voltaic cell has two half-cells joined by a wire and a salt bridge. Clean the metal electrodes with sandpaper and use a high-resistance voltmeter. An electrolytic cell needs a DC power supply, often with an ammeter in series.

Worked exampleA student needs 100.0 cm3\pu{100.0 cm3} of 0.0600 mol dm−3\pu{0.0600 mol dm-3} copper(II) sulfate solution, made from blue crystals of CuSOX4 ⋅ 5 HX2O\ce{CuSO4*5H2O}. Calculate the mass of crystals to weigh out, to three significant figures.

Try it first, then reveal one step at a time.

  1. Amount needed: n=CV=0.0600×0.1000=0.00600 moln = CV = 0.0600 \times 0.1000 = \pu{0.00600 mol}.
Worked exampleOutline how the student should turn the weighed crystals into 100.0 cm3\pu{100.0 cm3} of standard solution.

Try it first, then reveal one step at a time.

  1. Every step must keep all the solute and give exactly 100.0 cm3\pu{100.0 cm3}.
Check yourself
What volume of 0.0600 mol dm−3\pu{0.0600 mol dm-3} copper(II) sulfate solution, in cm3\pu{cm3}, must be diluted to make 100.0 cm3\pu{100.0 cm3} of 0.0150 mol dm−3\pu{0.0150 mol dm-3} solution? Give 3 significant figures.
Check yourself
A student's titres are 22.80 cm3\pu{22.80 cm3} (rough), 22.15 cm3\pu{22.15 cm3}, 22.40 cm3\pu{22.40 cm3} and 22.25 cm3\pu{22.25 cm3}. Calculate the mean of the concordant titres, in cm3\pu{cm3}, to 2 decimal places.

Separating, purifying and identifying

To separate a , use a property its parts don't share. Filtration removes an insoluble solid from a liquid; evaporation recovers a dissolved solid.

separates liquids with different boiling points, or a solvent from a solution. The vapour condenses in a sloping condenser and is collected.

heats a reaction for a long time. The condenser stands upright, so volatile substances condense and drip back instead of escaping (6.12).

Paper or thin-layer separates and identifies components. Spot the sample on a pencil baseline above the solvent, and cover the container. Compare each , RFR_\text{F}, with known substances run in the same conditions.

purifies a solid. Choose a solvent that dissolves it well when hot but poorly when cold. Dissolve it in the minimum of hot solvent, and let it cool slowly. The product crystallizes while soluble impurities stay dissolved. Filter, wash with a little cold solvent, and dry.

Melting point determination tests purity. A pure solid melts sharply at its data value. Impurities lower the melting point and widen the range.

Use light of the colour the solution absorbs most, such as orange-red light for a blue solution. Zero the instrument with a blank of solvent, measure the standards, then the sample. A spectrophotometer does the same at one exact wavelength.

Molecular modelling, with ball-and-stick kits or software, shows molecules in three dimensions. Use it to see shapes and bond angles and to compare isomers.

Worked exampleA student recrystallizes benzoic acid from water. Explain how measuring its melting point shows whether the product is pure.

Try it first, then reveal one step at a time.

  1. Compare the measured melting point with the data value.
Worked exampleA plating bath's copper(II) ion concentration is found by colorimetry. 10.00 cm3\pu{10.00 cm3} of bath liquid is diluted to 100.0 cm3\pu{100.0 cm3}. The calibration line is A=11.6cA = 11.6c (cc in mol dm−3\pu{mol dm-3}), and the diluted solution has A=0.348A = 0.348. Calculate the concentration in the bath.

Try it first, then reveal one step at a time.

  1. Diluted solution: c=0.34811.6=0.0300 mol dm−3c = \frac{0.348}{11.6} = \pu{0.0300 mol dm-3}.
Check yourself
Which technique recovers pure water from salt solution?
Check yourself
On a chromatogram, a spot is 3.6 cm\pu{3.6 cm} from the baseline and the solvent front is 8.0 cm\pu{8.0 cm} from the baseline. Calculate RFR_\text{F} to 2 decimal places.

Common mistakes

  • Writing just "water" in a method. Tap water adds ions, so say deionized or distilled water.
  • Giving a burette or pipette only a water rinse before filling it. Water left inside dilutes the solution, so finish by rinsing each with the solution it will hold.
  • Vague environmental answers such as "it pollutes water". Name the specific harm.
  • Saying impurities raise the melting point. They lower it and widen the melting range.
  • Using the anhydrous molar mass for a hydrated solid. Include the water of crystallization in MM.

Exam tips

  • "Suggest" a precaution: name the specific hazard and the measure that controls it, such as a fume cupboard for a toxic gas. "Wear goggles" alone is too general.
  • "Outline" a method: give the steps in order, name the apparatus (volumetric flask, pipette, burette) and the key detail, such as making up to the mark with deionized water.
  • Record each reading to the instrument's precision, with its unit. Trailing zeros count: 25.00 cm3\pu{25.00 cm3} from a pipette, not 25 cm3\pu{25 cm3}.

Key takeaways

Learn thisHazard: what could cause harm. Risk: how likely and serious it is, the way you work. Match each control measure to its hazard.
Learn thisRead at the bottom of the meniscus (the top for dark solutions), eye level. Burettes: two decimal places, to the nearest 0.05 cm3\pu{0.05 cm3}. Calibrate pH meters with buffers. Ammeter in series, voltmeter in parallel.
Learn thisStandard solution: weigh, dissolve in deionized water, transfer with rinsings to a volumetric flask, make up to the mark, invert.
Learn thisAverage only concordant titres (within 0.10 cm3\pu{0.10 cm3}). Dry to constant mass: repeat until two masses agree.
Learn thisDistillation collects the vapour; reflux returns it. Impurities lower a melting point and widen its range.
Learn thisColorimetry: zero with a blank, plot a calibration curve from standards, read the unknown's concentration from its absorbance.

Practise this

51 past-paper questions on Experimental design, safety and evaluation in the Chemistry HL bank, each with a mark scheme and a worked explanation.

Also: Analytical techniques (49)