Half-life
In a minute
The of an is the time it takes for half of its unstable nuclei to decay. In every half-life, the nuclei left, the mass of the isotope and the from it (once background is taken away) all halve. Learn to read half-life from tables and and to count half-lives in calculations. Extended adds and choosing the right isotope for a job.
You'll be able to
- Define half-life, and explain why it is the same however much of the isotope you start with.
- Read the half-life from a or a table of readings.
- Calculate a half-life, a time taken or the amount left by counting half-lives.
- Find the half-life from readings and decay curves that still include .
- Explain how the type of radiation and the half-life decide which isotope suits smoke alarms, food irradiation, sterilising equipment, thickness control, and the diagnosis and treatment of cancer.
Before you start3 quick questions on what this builds on
Revise first: 1.2 Motion, 5.1.1 The atom, 5.1.2 The nucleus, 5.2.1 Detection of radioactivity, 5.2.2 The three types of nuclear emission and 5.2.3 Radioactive decay
Half-life and decay curves
You can't predict when one will decay. But even a tiny sample holds billions of them. With so many, very nearly the same fraction decays in each equal time, so the whole sample behaves predictably.
As nuclei decay, fewer unstable nuclei are left. So fewer decay each second, and the from the sample falls too.
In each half-life, three things halve together: the number of unstable nuclei left, the mass of the isotope left and the count rate from it (with background ignored or subtracted).
Each has its own half-life, from less than a second to billions of years. It doesn't depend on how much you have: and of the same isotope take the same time to halve.
A is a graph of count rate (or nuclei or mass left) against time. It falls steeply at first, then less and less steeply: its gets smaller. It gets closer and closer to zero, but some of the isotope is still left after any whole number of half-lives.
Try it first, then reveal one step at a time.
- Read the count rate at the start: counts/minute at min.
- Halve the count rate, not the time: counts/minute.
- Draw a line across from until it meets the curve, then drop straight down from there: min.
- Check with a second halving: falls to between min and min, which is min again.
Half-life calculations
Most half-life questions are solved with a halving chain. In Core questions, background radiation can be ignored.
1. Write the starting value. 2. Halve it again and again, one arrow per half-life, until you reach the value you need. 3. Count the arrows, not the numbers. 4. Time taken = number of half-lives × half-life.
After , , and half-lives, the fraction left is , , and .
Try it first, then reveal one step at a time.
- Number of half-lives: .
- Halve the mass times: mg.
- Check: arrows, and .
Try it first, then reveal one step at a time.
- Start at counts/minute. Half of it is counts/minute.
- The table shows at days, so one half-life is days.
- Check: halves to between and days, which is days again.
Real readings include . The background doesn't come from the sample, so it doesn't halve. Only the (reading minus background) halves in each half-life.
1. Subtract the background from each reading. 2. Find the half-life from the corrected values. 3. If you need a measured reading, add the background back on at the end.
On a decay curve drawn from measured readings, the curve levels off at the background count rate, not at zero. Measure every halving from that level, not from the time axis.
Try it first, then reveal one step at a time.
- Subtract the background: the corrected count rates are , , and counts/minute.
- Half of is , which is reached at min.
- Check: halves to between and min, which is min again.
- Halving the raw gives , which is not in the table: that route goes wrong.
Choosing an isotope for a job Extended only
Two properties decide which isotope suits a job. The type of radiation decides how far it gets through materials and how much it ionises. The half-life decides how long the source keeps working.
If the half-life is too short, the source's count rate falls quickly, so it must be replaced often. Inside a patient's body, a long half-life is the problem: the body would stay radioactive long after the test.
Smoke alarm: an source ionises the air between two metal plates, so a small current flows. Smoke absorbs the alpha particles, the current falls and the alarm sounds. Alpha travels only a few centimetres in air, so it doesn't escape the alarm. The half-life is hundreds of years, so the source lasts the life of the alarm.
Irradiating food and sterilising equipment: radiation is used because it passes right through food, packaging and sealed medical equipment, killing bacteria inside. Equipment can be sterilised already sealed in its packet. Neither the food nor the equipment becomes radioactive. The source has a half-life of years, so it doesn't need replacing often.
Thickness control: radiation from a source passes through a sheet to a detector. If the sheet gets thicker, more radiation is absorbed and the count rate falls; a control unit then moves the rollers. Beta suits paper and thin sheets, and gamma suits thick metal sheets. The half-life must be long, so the count rate changes only because the thickness changes.
Diagnosing cancer: a gamma-emitting tracer is put into the body, and a detector outside shows where it collects. Gamma passes out through the body; alpha or beta would be absorbed inside, ionising cells. The half-life is a few hours: long enough for the scan, short enough that the body is soon not radioactive.
Treating cancer: in one method, beams of gamma rays from a source outside the body are aimed at the tumour from several directions. The tumour gets a large dose that kills its cells, while healthy tissue gets less. This source has a long half-life, so it keeps working for years.
Try it first, then reveal one step at a time.
- Say what each type of radiation would do with paper, then give one reason for the long half-life.
- Alpha particles would be stopped completely by the paper, so the count rate would not change with thickness. Gamma rays would pass through almost unchanged, so a small change in thickness would hardly change the count rate. Beta particles are partly absorbed by paper, so thicker paper gives a clearly lower count rate. A long half-life means the count rate does not fall noticeably because of decay, so any change is caused by the thickness.
Common mistakes
- Taking the first number of the halving chain as one half-life. Count the arrows in the halving chain, not the numbers.
- Halving the time instead of the count rate on a decay curve. Halve the vertical value; the half-life is the time taken to get there from your starting point.
- Drawing the decay as a straight line to zero, as if everything decays in two half-lives. The amount halves each time, so the curve flattens and never quite reaches zero.
- Thinking a bigger sample has a longer half-life. Half-life is the same for any amount of the isotope.
- Extended: halving a reading that still includes background. Subtract the background first, halve, then add it back if the question asks for the measured reading.
Exam tips
- "Calculate" questions: write the halving chain and the number of half-lives before the answer. These lines show your method and can earn marks even if the final answer slips.
- Paper 5/6: when you plot count rate against time, draw one smooth curve of best fit, not straight lines from point to point. Decay is random, so the points scatter a little about the curve.
- Extended: to "explain" a choice of isotope, make two separate points: the type of radiation with a penetration reason, and the half-life with a reason.
Key takeaways
Practise this
49 past-paper questions on Half-life in the 0625 Extended bank, each with a mark scheme and a worked explanation.