Detection of radioactivity
In a minute
is weak that is around you all the time, mostly from radon gas, rocks and buildings, food and drink, and cosmic rays. You measure ionising radiation with a detector connected to a counter, and give the in counts/s or counts/minute. Extended adds the : the reading minus the background.
You'll be able to
- State what background radiation is.
- Name the four sources that give most of the background radiation, and tell them apart from things that are not sources.
- Describe how a detector connected to a counter measures ionising radiation.
- Calculate a count rate in counts/s or counts/minute, and convert between the two.
- Use a measured background count rate to work out the corrected count rate of a source.
Before you start2 quick questions on what this builds on
Revise first: 5.1.1 The atom
Background radiation and where it comes from
Some nuclei are unstable. An unstable gives out radiation by itself to become more stable. This is .
This radiation can knock electrons out of the atoms it passes, turning them into ions. That makes it . It can damage living cells.
Most background radiation is natural. Four sources make the biggest contribution:
1. Radon gas in the air. Radon is a radioactive gas that seeps out of the ground from rocks such as granite. It is usually the largest single source.
2. Rocks and buildings. Rocks, soil, bricks and concrete contain small amounts of radioactive elements.
3. Food and drink. They contain tiny amounts of radioactive isotopes, so radiation also comes from inside your own body.
4. Cosmic rays. These are high-energy particles from space, from the Sun and from deeper in space. The atmosphere absorbs much of them, so you receive more at high altitude, for example in an aircraft.
A small part comes from human activity: medical X-rays and treatments, waste from nuclear power stations and old nuclear weapons tests.
Mobile phones, radio and TV transmitters, microwave ovens and visible light are not sources of background radiation. Their radiation is not ionising.
Try it first, then reveal one step at a time.
- Name the radiation that is always present, then pick two from the four main natural sources.
- The counts are caused by background radiation. Background radiation is ionising radiation that is present around us all the time. One natural source is radon gas in the air. Another natural source is cosmic rays from space.
Detector, counter and count rate
To measure ionising radiation, you connect a detector to a counter. The detector is often a Geiger–Müller tube. Each time it detects ionising radiation, it sends a small electrical pulse to the counter.
The counter adds up the pulses. Each pulse is one count.
To measure background radiation alone, you use just the detector and the counter, with every radioactive source taken away.
The number of counts depends on how long you count. So you compare readings using the : the number of counts in each second or each minute.
Count rate is measured in counts/s or counts/minute. There are 60 seconds in a minute, so a count rate in counts/minute is 60 times the same rate in counts/s.
Try it first, then reveal one step at a time.
- Change the time to seconds: .
- Check: in counts/minute it is , and . The two agree.
Radioactive emission is random. Even with nothing changed, the counter records a slightly different number of counts in each minute.
So one short reading is not reliable. Count for a long time, or repeat the reading and take the average.
Try it first, then reveal one step at a time.
- Add the counts: counts.
- Add the times: minutes.
Corrected count rate Extended only
When a detector is near a source, it counts radiation from the source and from the background together. The reading is too high for the source alone.
To find the source's own count rate, take the source away and record the background count rate on its own. Then take that away from the reading you got with the source in place. The result is the .
Both rates must be in the same unit before you subtract. You need the corrected count rate whenever you study the source itself, for example to find a half-life in 5.2.4.
Try it first, then reveal one step at a time.
- The counts/minute is the background, so subtract it.
Try it first, then reveal one step at a time.
- Background: counts in minutes, so counts/minute. Keep this value unrounded.
- Reading with the source: counts/minute.
- Both rates are now per minute.
Common mistakes
- Naming mobile phones, microwaves or radio masts as sources of background radiation. Their radiation is not ionising.
- Writing the unit of count rate the wrong way up, as minutes/count. Count rate is counts divided by time.
- Converting counts/minute to counts/s by multiplying by 60. A rate per second is smaller, so divide by 60.
- Thinking a background reading that changes from minute to minute means the detector is faulty. Radioactive emission is random.
- Extended: adding the background count rate instead of subtracting it, or subtracting a rate in counts/s from one in counts/minute.
Exam tips
- "State" what background radiation is with both ideas: it is ionising radiation, and it is present all the time.
- Paper 1/2 multiple choice on sources: cross out any option containing a non-ionising source (phones, microwaves, radio) or, if the question asks for natural sources, anything made by people.
- "Calculate" a count rate: write counts ÷ time with your numbers in, and give the unit, counts/s or counts/minute, that matches the time you used.
- Extended: in a corrected count rate question, check whether the background is given as a count or a rate, and per second or per minute, before you subtract.
Key takeaways
Practise this
13 past-paper questions on Detection of radioactivity in the 0625 Extended bank, each with a mark scheme and a worked explanation.