Activity and half-life
In a minute
In you can't say when one nucleus will decay, but a large sample behaves predictably. Its (decays per second) halves every , whatever the starting amount. A detector measures a , which also includes , so you subtract the background before you use half-lives.
You'll be able to
- Explain what activity, count rate and half-life mean, and read a half-life from a decay graph.
- Work out the activity, count rate or number of nuclei left after a whole number of half-lives, and the time taken to fall to a given value.
- Correct a count rate for background radiation, and explain why the measured count rate does not halve in one half-life.
Before you start3 quick questions on what this builds on
Revise first: 5.7 Radioactive decay
Activity, count rate and half-life
One nucleus decays at a random moment. But even a milligram of a radioactive material holds around nuclei, so the randomness averages out. The number decaying each second follows a clear pattern.
More undecayed nuclei means more decays each second. So as the sample decays, its activity falls.
You can't count every decay. A detector, such as a Geiger–Müller tube, records only some of them. The number it records per second (or per minute) is the .
If the source and detector stay in the same places, the count rate is a fixed fraction of the activity. So the count rate falls in step with the activity: when the activity halves, so does the count rate.
Half-life is the same whenever you start the clock. From 800 Bq to 400 Bq takes one half-life. So does 400 Bq to 200 Bq. It is a property of the nuclide, so it doesn't depend on the size of the sample.
Try it first, then reveal one step at a time.
- Find each time the activity halves. From to takes .
- From to takes .
- The two readings differ a little because points on a hand-drawn curve are uncertain. Take the mean: .
- The two values agree closely, as they should: the half-life is the same whatever value you start from.
Try it first, then reveal one step at a time.
- Marking point 1: the source emits radiation in all directions, so most of it never reaches the tube.
- Marking point 2: some radiation heading for the tube is absorbed by the air or the tube's window.
- Marking point 3: not every particle that enters the tube is detected.
- Conclusion: only a fraction of the decays are counted.
- The source emits radiation in all directions, so only a small fraction of it travels towards the tube. Some of the radiation heading for the tube is absorbed by the air or by the tube's window before it gets in. Not every particle that enters the tube is detected. So only some of the decays are counted, and the count rate is less than the activity.
Changes over whole half-lives
After one half-life, of the nuclei are left undecayed. After two, half of that half: . After three, . Each half-life multiplies what is left by .
is the number of half-lives that have passed, so . and are the values at the start. The count rate from the source (with background removed) follows the same rule.
These rules are not in the SL data booklet, so learn them. At SL, is always a whole number. A table of halvings works just as well as the formula.
Try it first, then reveal one step at a time.
- Number of half-lives: .
- Multiply by three times: .
- .
- Check with a table: Bq.
Try it first, then reveal one step at a time.
- Find the fraction left: .
- , so 4 half-lives have passed. As a table: .
- Time: .
Half-life decides which nuclide suits a job. A medical tracer needs a half-life of hours: long enough for a scan, short enough to keep the patient's dose low. A thickness gauge needs years, so its count rate stays steady during production.
Radioactive dating works the other way round. If a rock had none of the stable product when it formed, and none has escaped since, the ratio of product to parent nuclei tells you how many half-lives have passed. The parent's half-life must be similar in size to the age you want to measure.
Background radiation
Switch on a counter with no source nearby, and it still clicks. This is . It comes from radon gas in the air, rocks and building materials, cosmic rays, food and medical uses.
Background is random, but its average stays steady over an experiment. It doesn't come from your source, so it doesn't halve when your source does.
A counter near a source records the source's count rate plus the background. To find the source's part, measure the background with the source removed. Then subtract it from every reading. The result is the corrected count rate.
Try it first, then reveal one step at a time.
- Remove the background: from the source.
- Number of half-lives: .
- Decay only the source's part: .
- The counter still picks up the background, so add it back: .
To determine a half-life in the lab, measure the background for a long time, so its random variation averages out. Then record the count rate at regular times, correct every reading and plot the corrected count rate against time. Read several halvings off the curve and average them.
Try it first, then reveal one step at a time.
- Marking point 1: the measured count rate includes the background.
- Marking point 2: the background stays constant; it does not decay.
- Marking point 3: so the measured count rate takes longer than one half-life to halve.
- Marking point 4: the fix is to subtract the background from each reading first.
- The measured count rate is the count rate from the source plus the background count rate. The background stays constant on average, because it does not come from the source. Only the count rate from the source halves in one half-life. So the measured count rate takes longer than one half-life to halve, and the student's value is too long. The student should subtract the background from every reading, then find the time for the corrected count rate to halve.
Common mistakes
- Halving a count rate that still includes background. Subtract the background first; only the source's part decays.
- Thinking a sample has gone after two half-lives. A quarter is still undecayed; each half-life halves what is left.
- Saying a bigger sample has a longer half-life. A bigger sample has a bigger activity, but the half-life belongs to the nuclide.
- Giving activity in decays per minute and calling it becquerels. One becquerel is one decay per second.
- Treating the count rate as the activity. A detector catches only a fraction of the decays.
Exam tips
- "Determine" a half-life from a graph: show your construction lines, read two or more halvings and give the mean with its unit.
- "Calculate" a later count rate: write the subtraction of background, the number of half-lives and the halving as separate lines. Each one can earn a mark.
- In Paper 1A, options often include the answer you get by halving the measured count rate, or by forgetting to add the background back. Check which quantity the question asks for.
- "Explain" questions about count rate want the reason in steps: emitted in all directions, some absorbed, not all detected.
Key takeaways
Practise this
117 past-paper questions on Radioactivity and nuclear reactions in the Physics HL bank, each with a mark scheme and a worked explanation.