Cambridge IGCSE · 0654/62/O/N/20

IGCSE Co-ordinated Sciences 0654/62 October/November 2020

  • 1 hour 30 minutes
  • 60 marks
  • Variant 2
/ …
View
Loading original PDF…

At a glance

6 questions, 60 marks, across 6 topics. Most marks: Chemical reactions (13 marks, 22%), Electricity and magnetism (13 marks, 22%) and Biological molecules (12 marks, 20%).

Practise by topic

Pick a topic for more questions like it.

Question by question

6 questions · 60 marks

  1. Q1Biological molecules, Earlier syllabus topics, Cells, Gas exchange in humans12 marks
  2. Q2Cells, Earlier syllabus topics, Biological molecules8 marks
  3. Q3Earlier syllabus topics, Acids, bases and salts7 marks
  4. Q4Earlier syllabus topics, Chemical reactions13 marks
  5. Q5Electricity and magnetism, Earlier syllabus topics13 marks
  6. Q6Motion, forces and energy7 marks

Worked answers

Step-by-step solutions, with the mark-scheme points each step earns.

Q1Biological molecules, Cells, Gas exchange in humans12 marks
(a)(i)1 mark

The table records a reading every minute, so the column heading needs a unit of time that matches.

  1. The times run 0, 1, 2, 3, 4, 5 and the readings were taken every minute, so write the unit in the heading: time / min.
    B1

Answermin (minutes)

(a)(ii)1 mark

A small, accurate volume of liquid is measured with apparatus designed for it.

  1. 2 cm32\text{ cm}^3 is a small volume of liquid, so use a syringe (or a graduated pipette) to measure it accurately.
    B1

Answera syringe

Watch outNaming a beaker or a measuring cylinder; these are not accurate enough for 2 cm32\text{ cm}^3.

(b)(i)2 marks

Iodine is small enough to pass through the tubing, starch is too large, and iodine turns blue-black with starch.

  1. Bag of starch solution: small iodine molecules diffuse through the Visking tubing into the bag.
  2. Iodine reacts with the starch inside, giving the blue-black colour.
  3. Beaker A: starch molecules are large, so they cannot diffuse out through the tubing. There is no starch in the beaker, so the iodine solution stays brown.
    B2

AnswerBag: iodine moves in and turns blue-black with starch. Beaker A: starch cannot move out (large molecules), so it stays brown.

(b)(ii)1 mark

Compare bag X with the starch bag: the colour it ends up shows whether iodine met starch.

  1. The solution in bag X turns brown, not blue-black, even though iodine entered. So there is no starch in solution X.
    B1

AnswerSolution X contains no starch.

(c)(i)1 mark

Find the first row of the table where bag X is no longer colourless.

  1. Bag X is colourless at 3 minutes and brown at 4 minutes, so the change happens at 4 minutes (between 3 and 4 minutes).
    B1

Answer4 minutes

(c)(ii)1 mark

Both bags are in the same iodine solution, so the same process drives the change in each.

  1. The same iodine molecules diffuse into both bags through the same type of tubing, at the same rate, so both change colour together.
    B1

AnswerIodine enters both bags at the same rate by diffusion.

(d)1 mark

Anything left on the outside of the bag could affect the result in the beaker.

  1. Rinsing removes starch or solution X spilt on the outside of the bag. This avoids contamination of the iodine solution in the beaker.
    B1

AnswerTo remove starch (or solution) from the outside and avoid contamination.

(e)1 mark

Higher temperature means faster molecules, so diffusion is faster.

  1. Iodine diffuses into bag A faster, so bag A turns blue-black sooner than at 4 minutes.
    B1

AnswerThe bag turns blue-black faster (in less time).

(f)3 marks

The test for reducing sugar is Benedict's solution with heating.

  1. Add Benedict's solution to a sample of solution X.
    B1
  2. Heat the mixture, for example in a hot water bath.
    B1
  3. A positive result is a colour change from blue to green, yellow, orange or red.
    B1

AnswerBenedict's solution, heat; goes green / yellow / orange / red.

Watch outUsing iodine or biuret solution, which test for starch and protein.

Q2Cells, Biological molecules8 marks
(a)3 marks

A good biological drawing is a clear, enlarged outline with the central detail, drawn from what is actually seen.

  1. Draw a single clear, continuous outline of the slice with a sharp pencil, with no gaps or sketchy lines (shading is allowed).
  2. Make the drawing larger than the photograph so it fills most of the box.
  3. Draw the central detail: the cluster of seed-like tissue in the middle, in the right position and shape.
    B3

AnswerClear continuous outline; larger than the photograph; central detail drawn.

(b)(i)1 mark

Measure straight across from A to B with a ruler in millimetres.

  1. Place the ruler on the line from A to B and read the length: 43 mm (within 1 mm of this).
    B1

Answer43±1 mm43 \pm 1\text{ mm}

(b)(ii)1 mark

Draw the equivalent line on your own drawing and measure it.

  1. Draw a line across your drawing between the points matching A and B, and measure it to the nearest mm. This answer depends on the size of your drawing.
    B1

AnswerA drawn line with the correct measurement of it, in mm.

(b)(iii)1 mark

Magnification is drawing size divided by actual size, with both in the same unit.

  1. Substitute your measurements: m=diameter on drawing43m = \frac{\text{diameter on drawing}}{43}, then round sensibly, for example a 86 mm line gives m=8643=2m = \frac{86}{43} = 2 (or ×2\times 2).
    B1

Answerm=diameter on drawingactual diameterm = \frac{\text{diameter on drawing}}{\text{actual diameter}} using your own measurements, correctly calculated and rounded (no units).

(c)(i)1 mark

Protein is tested with biuret solution.

  1. The test solution for protein is biuret solution.
    B1

AnswerBiuret

(c)(ii)1 mark

Biuret goes from blue to a purple colour when protein is present.

  1. A positive result is a colour change from blue to purple (lilac, mauve or violet).
    B1

AnswerPurple (lilac / mauve / violet)

Q3Acids, bases and salts7 marks
(a)(i)1 mark

Stirring helps the soluble compound dissolve so it can be separated from the insoluble one.

  1. Stirring makes the soluble compound dissolve more quickly and fully in the water.
    B1

AnswerTo dissolve the soluble compound more quickly

(a)(ii)1 mark

Carbon dioxide is identified with limewater.

  1. Bubble the gas through limewater. A positive result is that the limewater turns milky.
    B1

AnswerLimewater turns milky

(a)(iii)1 mark

A residue that fizzes with acid to give carbon dioxide contains a carbonate.

  1. Carbonates react with acid to release carbon dioxide, so an anion in J is carbonate, CO32−\text{CO}_3^{2-}.
    B1

AnswerCarbonate, CO32−\text{CO}_3^{2-}

(a)(iv)1 mark

A light blue precipitate insoluble in sodium hydroxide that dissolves in excess ammonia to a dark blue solution is the copper(II) result.

  1. Copper(II) hydroxide is a light blue precipitate with sodium hydroxide, and the precipitate dissolves in excess ammonia to give a dark blue solution. The cation is copper, Cu2+\text{Cu}^{2+}.
    B1

AnswerCopper, Cu2+\text{Cu}^{2+}

(a)(v)1 mark

The residue is wet with the solution of the soluble compound.

  1. Washing removes the soluble compound from the residue, preventing contamination of the sample being tested.
    B1

AnswerTo prevent contamination by the soluble compound

(b)1 mark

A white precipitate with acidified barium nitrate is the test for sulfate.

  1. Barium ions combine with sulfate ions to make white barium sulfate. The other anion is sulfate, SO42−\text{SO}_4^{2-}.
    B1

AnswerSulfate, SO42−\text{SO}_4^{2-}

(c)1 mark

Filtering needs a funnel lined with filter paper.

  1. Draw a filter funnel with a cone of filter paper inside it and the stem leading into a container. Label the filter paper and the filter funnel.
    B1

AnswerLabelled filter funnel containing filter paper

Q4Chemical reactions13 marks
(a)(i)3 marks

Match each stopwatch reading to its experiment number from the labels, then round to the nearest second.

  1. Experiment 1 is 150 s150\text{ s} and experiment 2 is 35 s35\text{ s} (already whole seconds).
  2. Experiment 3 is 15.4 s15.4\text{ s}, which rounds to 15 s15\text{ s}.
  3. The result labelled 20 cm320\text{ cm}^3 acid belongs to experiment 4: 11.6 s11.6\text{ s} rounds to 12 s12\text{ s}. Experiment 5 is 10.2 s10.2\text{ s}, which rounds to 10 s10\text{ s}.
    B3

Answer1: 150 s; 2: 35 s; 3: 15 s; 4: 12 s; 5: 10 s

(a)(ii)1 mark

A larger surface area speeds up the reaction too much to time it.

  1. Powder has a very large surface area, so the reaction would be too fast and the reaction time too short to measure accurately.
    B1

Answerthe reaction would be too fast / the reaction time would be too short

(a)(iii)2 marks

Control everything that affects the rate except the acid concentration being tested.

  1. Keep the total volume of the solution (mixture) the same, 25 cm325\text{ cm}^3 each time.
    B1
  2. Keep the temperature the same. The mass, length or thickness of the magnesium ribbon (30 mm) is also controlled.
    B1

Answerany two of: volume of solution; temperature; mass or length or thickness of magnesium

(b)(i)3 marks

Put volume of acid on the horizontal axis (the variable the student chose) and reaction time on the vertical axis, then plot the five points.

  1. Label the horizontal axis 'volume of dilute hydrochloric acid / cm3^3' and the vertical axis 'reaction time / s', with units.
    B1
  2. Choose a linear scale so the plotted points cover at least half of the grid, for example 0 to 150 s upwards and 10 to 25 cm3^3 across.
    B1
  3. Plot all five points to within half a square: (10,150)(10, 150), (12.5,35)(12.5, 35), (15,15)(15, 15), (20,12)(20, 12) and (25,10)(25, 10).
    B1

Answerlabelled axes with units; linear scale covering over half the grid; all five points plotted correctly within half a square

(b)(ii)1 mark

The points follow a smooth curve, not straight lines.

  1. Draw one smooth curve of best fit through the points, falling steeply then levelling off.
    B1

Answera smooth curve of best fit through the points

(c)2 marks

State the direction of the trend, then say that it is not a straight line.

  1. As the volume of acid increases, the reaction time decreases.
    B1
  2. The relationship is not linear: the time falls steeply at first (for example 150 s to 35 s) and then levels off (for example 12 s to 10 s).
    B1

Answeras volume increases the reaction time decreases, and the relationship is not linear

(d)1 mark

A measuring cylinder with a smaller scale gives finer readings for a small volume.

  1. The volume of water in experiment 4 is only 5.0 cm35.0\text{ cm}^3. A 10 cm310\text{ cm}^3 cylinder has smaller scale divisions, so there is a smaller error or lower uncertainty in the reading.
    B1

Answersmaller error / lower uncertainty in the reading

Q5Electricity and magnetism13 marks
(a)(i)2 marks

A voltmeter measures the p.d. across a component, so it must be connected in parallel with the lamp.

  1. Draw the voltmeter symbol, a circle containing the letter V.
    ✓
  2. Connect it in parallel with the lamp: one wire from each side of the lamp to the voltmeter, so it does not sit in the main loop.
    ✓

AnswerA circle containing V, connected in parallel across the lamp

Watch outPlacing the voltmeter in series with the lamp, in the main loop.

(a)(ii)2 marks

Read each meter scale carefully, using the size of the smallest division.

  1. The ammeter needle sits between 0 and 0.5, a little below 0.2. Each small division is 0.02 A0.02\text{ A}, so I=0.19 AI = 0.19\text{ A}.
    ✓
  2. The voltmeter needle sits just below 2. Each small division is 0.1 V0.1\text{ V}, so V=1.8 VV = 1.8\text{ V}.
    ✓

AnswerI=0.19I = 0.19, V=1.8V = 1.8

(a)(iii)1 mark

Current is measured in amperes and potential difference in volts, matching the meters used.

  1. The ammeter A gives current in amperes, so the column heading is I/AI/\text{A}. The voltmeter V gives p.d. in volts, so the heading is V/VV/\text{V}.
    ✓

AnswerA for current, V for potential difference

(a)(iv)1 mark

Leaving current flowing continuously has unwanted effects, so the circuit is only on when taking a reading.

  1. Keeping the switch closed would let the cell run down, or let the wire overheat. Opening the switch between readings prevents this.
    ✓

AnswerSo the cell does not run down or the wire does not overheat

(b)(i)1 mark

Use R=V/IR = V/I with the readings for l=40.0 cml = 40.0\text{ cm} from Table 5.1.

  1. From the table, V=1.4 VV = 1.4\text{ V} and I=0.17 AI = 0.17\text{ A}.
  2. Substitute:
    R=VI=1.40.17=8.2 ΩR = \frac{V}{I} = \frac{1.4}{0.17} = 8.2\ \Omega
    ✓

Answer8.2 Ω8.2\ \Omega

(b)(ii)1 mark

Compare the resistance values going down Table 5.2 as the length increases.

  1. As ll rises from 15.0 cm to 80.0 cm, RR falls from 9.5 Ω9.5\ \Omega to 7.7 Ω7.7\ \Omega. So the resistance of the lamp decreases as the length of wire increases.
    ✓

AnswerThe resistance of the lamp decreases

(c)(i)1 mark

Use P=V×IP = V \times I with the readings for l=65.0 cml = 65.0\text{ cm}.

  1. From Table 5.1, V=1.2 VV = 1.2\text{ V} and I=0.15 AI = 0.15\text{ A}.
  2. Substitute:
    P=V×I=1.2×0.15=0.18 WP = V \times I = 1.2 \times 0.15 = 0.18\text{ W}
    ✓

Answer0.18 W0.18\text{ W}

(c)(ii)1 mark

Lower power means less energy transferred each second as light, which the student can see.

  1. As the length increases, the lamp gets dimmer (less bright). The current or the voltage also gets less.
    ✓

AnswerThe lamp gets dimmer

(c)(iii)1 mark

If RR were directly proportional to PP, the ratio R/PR/P would be constant.

  1. Calculate the ratio for two lengths: at 15.0 cm, 9.5/0.34=289.5 / 0.34 = 28; at 80.0 cm, 7.7/0.13=597.7 / 0.13 = 59. The ratio is not constant, and RR falls while PP falls by a much larger fraction. So the data do not support the suggestion.
    ✓

AnswerNo, because R/PR/P is not constant

(d)1 mark

If the lamp is intact, current should flow when it is in a working circuit.

  1. Check that the ammeter gives a reading. A current in the circuit shows the lamp filament is not broken.
    ✓

AnswerCheck that the ammeter gives a reading

(e)1 mark

A component that gives a variable resistance lets the current and p.d. be changed smoothly.

  1. A rheostat (variable resistor) replaces the resistance wire.
    ✓

AnswerRheostat (variable resistor)

Q6Motion, forces and energy7 marks

Change only the original length of the spring, add the same load to each, and measure how far each stretches so the extensions can be compared fairly.

  1. Method: clamp a spring from the stand and measure its original length with the rule. Hang the 100 g mass hanger and two 100 g masses (a fixed load of 300 g) on the spring, then measure its new length.
    ✓
  2. Repeat the experiment with springs of different original lengths, using the same 300 g load each time.
    ✓
  3. Key variables to control: use springs of the same diameter and the same material, and hang the same mass on each spring.
    ✓
  4. Accuracy: remove the mass and check the spring returns to its original length, so the spring has not been over-stretched.
    ✓
  5. Processing: calculate extension as new length −- original length. Repeat for each spring and take an average extension.
    ✓
  6. Table: columns headed original length of spring / mm, length after mass added / mm and extension / mm, with units.
    original length / mm | length with mass added / mm | extension / mm
    ✓
  7. Conclusion: compare the extensions for the different original lengths and see whether longer springs give longer or shorter extensions. Plot a graph of extension against original length and look for the trend.
    ✓

AnswerMeasure original and loaded lengths of springs of different lengths (same diameter, material and mass), calculate extension, record in a table with units, then compare extensions and look for a trend on a graph.

Also listed as0654/62/O/N/20 · 0654/62 O/N 20 · 0654_w20_qp_62 · 0654_w20_ms_62 · 0654 w20 qp 62 · 0654 October/November 2020 Paper 62