Cambridge IGCSE · 0620/61/O/N/20
IGCSE Chemistry 0620/61 October/November 2020
- 1 hour
- 40 marks
- Variant 1
At a glance
4 questions, 40 marks, across 1 topic. Most marks: Practical skills and investigations (40 marks, 100%).
Practise by topic
Pick a topic for more questions like it.
Question by question
4 questions · 40 marks
Worked answers
Step-by-step solutions, with the mark-scheme points each step earns.
Q1Practical skills and investigations8 marks
Identify each piece of apparatus from its position in the diagram.
- A, the item in the top of the flask, is a thermometer.✓
- B, the water-jacketed tube that cools the vapour to a liquid, is a (Liebig) condenser.✓
AnswerA: thermometer; B: (Liebig) condenser
Separating liquids with different boiling points using a fractionating column is a specific method.
- The column packed with beads separates the alcohols, so the method is fractional.✓
- Heating a liquid and condensing its vapour is distillation, so the method is fractional distillation.✓
AnswerFractional distillation
Think about the property of alcohols that makes a naked flame dangerous.
- Alcohols are flammable, and the electric heater and water bath avoid a naked flame.✓
AnswerAlcohols are flammable
Use the boiling points: ethanol () boils first and propanol () next.
- Heat the mixture to remove the ethanol, which has the lowest boiling point.✓
- Collect the propanol when the thermometer reads .✓
AnswerHeat to remove the ethanol, then collect propanol at
Compare butanol's boiling point with the highest temperature the water bath can reach.
- Butanol boils at , above , and a water bath cannot get hotter than because water boils.✓
AnswerWater boils at , so the water bath cannot reach butanol's boiling point of
Q2Practical skills and investigations17 marks
Read each meniscus at eye level against the scale, using the size of one division between the labelled lines.
- Experiment 2: the liquid surface sits between 10 and 20, at .
- Experiment 3: the surface is between 20 and 30, at ; experiment 4: between 20 and 30 and close to 30, at .
- Experiments 5, 6 and 7: read the surface from the scale as , and .B2
Answer, , , , , (experiments 2 to 7)
Mass rises steadily while lead(II) nitrate is the limiting reactant, then levels off once potassium iodide runs out, so two straight lines are needed.
- Plot all seven points (volume, mass): , , , , , , , each as an accurate cross or dot.M1M2
- Use a ruler to draw one straight line through the first four points, which rise steadily.M3
- Use a ruler to draw a horizontal straight line through the last three points at .M4
- Extend both lines until they cross, at about .M5
AnswerPoints plotted correctly; a ruled sloping line through the first four points; a ruled horizontal line through the last three points; both lines extended so that they meet.
Read the graph at using the sloping line, and show the construction lines.
- Draw a vertical line up from on the volume axis to the sloping line, then a horizontal line across to the mass axis.B1
- Read the mass where the horizontal line meets the axis: about .B1
AnswerAbout , read from the sloping line with the working lines shown on the grid
Once one reactant is used up, adding more of the other cannot make more product.
- In experiments 5, 6 and 7 all the potassium iodide has reacted, so extra lead(II) nitrate cannot form any more precipitate.B1
AnswerAll the potassium iodide has been used up (reacted)
Half the concentration means half the amount of potassium iodide, so the maximum precipitate halves and is reached with half the volume of lead(II) nitrate.
- The maximum mass is half of : , so the horizontal part of the new graph is at .B1
- The line reaches this maximum at half the volume at which the plotted graph levels off (about instead of ), then stays horizontal.B1
AnswerA line rising to a maximum of at half the volume where the plotted graph levels off, then horizontal
Compare how well each piece of apparatus measures a volume.
- A pipette is more accurate (more precise) than a measuring cylinder.B1
AnswerA pipette is more accurate / precise than a measuring cylinder
A pipette is built to deliver one fixed volume only.
- A pipette can only measure , but the lead(II) nitrate volume changes in each experiment.B1
AnswerA pipette measures only a fixed volume of
Separate an insoluble solid from a liquid by filtering, then clean and dry it before weighing.
- Filter the reaction mixture to collect the lead(II) iodide as residue.✓
- Wash the residue with distilled water to remove the soluble potassium nitrate.✓
- Dry the residue, then weigh it.✓
AnswerFilter; wash the residue; dry it and weigh it
Q3Practical skills and investigations, Chemistry of the environment, Organic chemistry9 marks
A gas that turns damp red litmus paper blue is alkaline.
- Aluminium reacts with hot aqueous sodium hydroxide in the presence of nitrate ions to give a gas that turns damp red litmus blue. The only common alkaline gas is ammonia.B1
AnswerAmmonia
Identify the cation from tests 1 to 3 and the anion from test 4.
- A white precipitate with aqueous ammonia that is insoluble in excess, and with sodium hydroxide that dissolves in excess to a colourless solution, shows the cation is aluminium, .B1
- Test 3 gives ammonia when aluminium foil is warmed with the sodium hydroxide mixture, which happens only with nitrate ions; and test 4 gives no precipitate with silver nitrate, so there is no chloride, bromide or iodide. The anion is nitrate, .B1
AnswerAluminium nitrate: and
Universal indicator colour shows the pH.
- Orange universal indicator paper means a pH of about 3 to 5, so solution Y is weakly acidic.B1
AnswerSolution Y is (weakly) acidic
Iron(II) ions () form a green hydroxide precipitate with an alkali.
- Aqueous ammonia gives a green precipitate.✓
- The precipitate is insoluble in excess ammonia, so it stays unchanged.✓
AnswerGreen precipitate; insoluble in excess (no further change)
Sulfate ions do not react with dilute hydrochloric acid, and iron(II) ions stay in solution.
- Nothing is formed or given off, so there is no change.B1
AnswerNo change
Acidified potassium manganate(VII) turns colourless only with a reducing gas such as sulfur dioxide.
- No sulfur dioxide is given off, because sulfate is not sulfite, so the filter paper stays purple.B1
AnswerNo change (the paper remains purple)
Acidified barium nitrate is the test for sulfate ions.
- Sulfate ions react with barium ions to form insoluble barium sulfate, a white precipitate.B1
AnswerWhite precipitate
Q4Practical skills and investigations, Chemistry of the environment6 marks
Use the two solvents one after the other: each dissolves one compound, and the silicon dioxide is insoluble in both, so it is left behind.
- Put the mixture in a suitable container such as a beaker or flask.✓
- Add water to dissolve the copper(II) sulfate (cetyl alcohol and silicon dioxide do not dissolve in water), and stir to help it dissolve.✓
- Filter the mixture. The filtrate is copper(II) sulfate solution; the residue is cetyl alcohol and silicon dioxide.✓
- Evaporate the water from the filtrate to obtain copper(II) sulfate.✓
- Add propanone to the residue to dissolve the cetyl alcohol, then filter. Wash the residue with propanone, so it is left as silicon dioxide. Evaporate the propanone from the filtrate to obtain cetyl alcohol.✓
- Dry the residue to obtain pure silicon dioxide.✓
AnswerAdd water, stir and filter; evaporate the filtrate to get copper(II) sulfate. Add propanone to the residue, filter, and evaporate the filtrate to get cetyl alcohol. Wash and dry the residue to get silicon dioxide.
Also listed as0620/61/O/N/20 · 0620/61 O/N 20 · 0620_w20_qp_61 · 0620_w20_ms_61 · 0620 w20 qp 61 · 0620 October/November 2020 Paper 61