Cambridge IGCSE · 0620/61/O/N/19
IGCSE Chemistry 0620/61 October/November 2019
- 1 hour
- 40 marks
- Variant 1
At a glance
4 questions, 40 marks, across 1 topic. Most marks: Practical skills and investigations (40 marks, 100%).
Practise by topic
Pick a topic for more questions like it.
Question by question
4 questions · 40 marks
Worked answers
Step-by-step solutions, with the mark-scheme points each step earns.
Q1Practical skills and investigations8 marks
The labelled container holding the ice and the U-tube is a common piece of laboratory glassware.
- The box names the glass container holding the ice: a beaker.✓
Answerbeaker
Burning ethanol makes water as a gas, and the ice-cooled tube turns it into a liquid.
- Burning ethanol produces steam (water vapour).✓
- In the U-tube, cooled by the ice, the steam condenses to liquid water.✓
Answersteam / water vapour condenses when cooled by the ice
Use a reagent that changes colour in the presence of water.
- Test: add the liquid to anhydrous copper(II) sulfate (or use cobalt(II) chloride paper).✓
- Observation: anhydrous copper(II) sulfate turns blue, or cobalt(II) chloride paper turns pink.✓
Answeranhydrous copper(II) sulfate turns blue (or cobalt(II) chloride paper turns pink)
The products are gases, so something must move them through the apparatus.
- The suction pump draws the gaseous products through the apparatus, from the funnel through the U-tube and into the limewater.✓
Answerto suck the gases / products through the apparatus
Complete combustion of ethanol gives carbon dioxide as well as water, and carbon dioxide reacts with limewater.
- The limewater turns milky.✓
- This is because carbon dioxide is formed when ethanol burns.✓
Answerthe limewater turns milky because carbon dioxide is formed
Q2Practical skills and investigations17 marks
Read the level of the water surface against the cylinder scale, remembering the cylinder is inverted so its numbers increase downwards.
- Read the gas volume at each time from the meniscus in each diagram.
- The completed table of volumes is 0, 27, 48, 62, 65, 74, 76, 77 and 77 for 0, 10, 20, 30, 40, 50, 60, 70 and 80 s.B2
Answer0, 27, 48, 62, 65, 74, 76, 77, 77 cm
Plot each (time, volume) point, then draw one smooth best-fit curve that ignores the point that does not fit the trend.
- Plot every point accurately, for example , , and . All points plotted correctly earns two marks.B2
- Draw a smooth best-fit curve through the points, leaving out the anomalous point at , . The curve is steep at first and levels off at about .B1
Answerall points plotted correctly and a smooth best-fit curve omitting the anomalous point at 40 s / 65 cm
An anomalous point is one that breaks the smooth trend of the rest.
- Circle the point at and . The rise from to is too small compared with the neighbouring gaps (about 13 then 9), so it lies below the curve.B1
Answerthe point at 40 s / 65 cm
Read across from on the curve and down to the time axis.
- Draw a horizontal line from on the volume axis to your curve, then a vertical line down to the time axis.B1
- Read the time where the vertical line meets the axis. This value, taken from your graph, is the time to collect .B1
Answerthe time read from your own graph at 40 cm, with the construction lines shown
A source of error is a flaw in measuring the gas, and the improvement removes it with more precise equipment.
- Source of error: a measuring cylinder is imprecise for these small volumes, so readings are inaccurate.B1
- Improvement: use a gas syringe or a measuring cylinder.B1
Answerimprecise cylinder, improved by a gas syringe or measuring cylinder
Subtract the volume at 10 s from the volume at 30 s.
- .B1
Answer
Divide the gas volume by the time interval, which is .
- Average rate .B1
- The unit is volume per time, so the rate is .B1
Answer
The gas is collected over water, and carbon dioxide dissolves in water.
- The actual volume of gas collected was lower than .B1
- Some of the carbon dioxide dissolved in the water in the trough, so less reached the measuring cylinder.B1
Answera lower volume, because some carbon dioxide dissolved in the water
A lower temperature means slower reaction, but the same acid and carbonate mean the same final volume.
- Draw a curve labelled L that is less steep and lies below the original curve.B1
- Let L rise gradually and approach the same final volume as the original curve, because the amounts of reactants are unchanged.B1
Answercurve L below the original, approaching the same final level
Q3Practical skills and investigations, Organic chemistry9 marks
Zinc ions form a white hydroxide precipitate with a few drops of sodium hydroxide.
- The colour of the solid formed is white.✓
- It is a precipitate, zinc hydroxide.✓
Answerwhite precipitate
Zinc hydroxide is amphoteric, so it dissolves in excess sodium hydroxide.
- The precipitate dissolves, giving a colourless solution.✓
Answerprecipitate dissolves / colourless solution
Zinc ions also precipitate with a few drops of aqueous ammonia.
- A white precipitate forms.✓
Answerwhite precipitate
Zinc hydroxide dissolves in excess ammonia, unlike the hydroxides of many other metals.
- The precipitate dissolves, giving a colourless solution.✓
Answerprecipitate dissolves / colourless solution
Nitrate ions are reduced to ammonia by aluminium in sodium hydroxide.
- Bubbles (effervescence) are seen as ammonia gas forms.✓
- The gas turns damp red litmus paper blue, because ammonia is alkaline.✓
Answerbubbles / effervescence; litmus turns blue
Use the flame test for the cation and the silver nitrate test for the anion.
- The red flame shows lithium ions.✓
- The yellow precipitate with acidified silver nitrate shows iodide ions. B is lithium iodide.✓
Answerlithium iodide
Q4Practical skills and investigations6 marks
To compare solubility, give each solvent the same volume and the same mass of iodine, then see how much is left undissolved.
- Measure a known volume of ethanol, for example , into a beaker or flask.B1
- Add a known mass of iodine and stir or shake until no more dissolves, so that some solid iodine remains.B1
- Filter the mixture to collect the undissolved iodine.B1
- Dry the residue and weigh it. The mass dissolved is the starting mass minus the mass of undissolved iodine.B1
- Repeat with hexane, using the same volume of solvent, the same mass of iodine and the same temperature.B1
- Conclusion: the solvent that left less undissolved iodine dissolved more, so iodine is more soluble in that solvent.B1
AnswerSame volume of each solvent and same mass of iodine; stir, filter, dry and weigh the undissolved iodine; the solvent leaving the least undissolved iodine is the better solvent.
Watch outUsing different volumes of the two solvents or different masses of iodine, which makes the comparison unfair.
Also listed as0620/61/O/N/19 · 0620/61 O/N 19 · 0620_w19_qp_61 · 0620_w19_ms_61 · 0620 w19 qp 61 · 0620 October/November 2019 Paper 61