Cambridge IGCSE · 0610/53/M/J/21
IGCSE Biology 0610/53 May/June 2021
- 1 hour 15 minutes
- 40 marks
- Variant 3
At a glance
2 questions, 40 marks, across 2 topics. Most marks: Plant nutrition (21 marks, 53%) and Human nutrition (19 marks, 48%).
Practise by topic
Pick a topic for more questions like it.
Question by question
2 questions · 40 marks
- Q1Human nutrition19 marks
- Q2Plant nutrition21 marks
Worked answers
Step-by-step solutions, with the mark-scheme points each step earns.
Q1Human nutrition19 marks
The final concentration is the share of 1.00% solution in the 4 cm total.
- Beaker C has 3 cm of 1.00% vitamin C in 4 cm total, so .✓
Answer0.75 %
Set up a table with a row for each of the four beakers and a column for the number of drops of DCPIP.
- Draw a table with at least two columns and a header row.✓
- Use suitable headings with units: percentage concentration of vitamin C / % (or beaker) and number of drops of DCPIP.✓
- Record four values, one drop count for each of A, B, C and D.✓
- The values should show the expected trend: more drops for D (1.00%) than for A (0.25%).✓
AnswerA table with a header row, suitable headings, four drop counts, and more drops for D than for A.
Describe how the drops change with concentration.
- Higher concentrations of vitamin C need a greater number of drops of DCPIP to turn the solution blue, because more vitamin C reacts with the DCPIP.✓
AnswerThe higher the vitamin C concentration, the more drops of DCPIP are needed.
Report the drop count from your own practical.
- Record the number of drops of DCPIP added to test-tube H as a whole number.✓
AnswerA number of drops (from your own results)
Compare the drops for H with the drops in A to D in your table, then read the concentration.
- Find the beaker (or a point between two beakers) in your table with a similar number of drops to H, and use its concentration as the estimate for H.✓
AnswerA concentration calculated from your own results (for example between 0.25% and 1.00%)
Constant variables are things the method keeps the same for every test-tube.
- The concentration of the DCPIP solution is the same each time.✓
- The volume of vitamin C solution in each test-tube is the same (0.5 cm), as is the type of indicator.✓
AnswerAny two: concentration of DCPIP, volume of vitamin C solution, type of indicator.
Swirling affects how well the reactants meet.
- Swirling mixes the contents, so all of the DCPIP reacts with the vitamin C and the solution has time to go colourless.✓
AnswerTo mix the contents so that all of the DCPIP reacts with the vitamin C.
Think of changes that give more precise readings or a finer scale.
- Use intermediate concentrations of vitamin C solution, so the drink can be compared with closer values.✓
- Measure the volume of DCPIP added instead of counting drops, since volumes are more precise.✓
AnswerAny two: use intermediate concentrations, measure the volume of DCPIP, use a larger volume of vitamin C or a lower DCPIP concentration, keep the temperature constant, plot a graph and read off the value from the line of best fit.
Drops are not a fixed unit of volume.
- The drop size is variable (unknown), so the number of drops does not give an exact volume. The end point may also be between two drops.✓
AnswerDrop size is variable, or the exact end-point could be between two drops.
Give the reagent, any step needed, and the positive colour for each food test.
- Protein: add biuret solution to the health drink.✓
- A positive result for protein is a purple colour.✓
- Glucose: add Benedict's solution to the health drink.✓
- Heat the mixture, for example in a hot water bath.✓
- A positive result for glucose is a colour change to green, yellow, orange or brick-red.✓
AnswerProtein: biuret solution, purple. Glucose: Benedict's solution and heat, green/yellow/orange/brick-red.
Q2Plant nutrition21 marks
A good biological drawing is large, drawn with a clean continuous outline, and includes the details visible on the real leaf.
- Make the drawing big: it should use more than half of the space provided.✓
- Use a continuous, clear outline with no shading.✓
- Draw the details seen on leaf L1, such as the leaf shape and edge, the main vein and the side veins, the way the supervisor's report describes them.✓✓
AnswerMore than 50% of the space used; continuous outline with no shading; two correct details of the leaf, such as the shape of the edge and the veins
Magnification = length in the drawing actual length, so both lengths must be measured in the same unit.
- Mark on your drawing the line along which you measured the leaf length.✓
- Measure that line with a ruler, with its unit (mm), and measure the actual length of leaf L1 in the same unit.✓
- Divide the drawn length by the actual length, using your own measurements:✓
AnswerMeasurement indicated on the drawing; correct length of the line in mm; magnification = drawn length actual length, from your own measurements
Carbon dioxide concentration is the variable the student chose, so it goes on the x-axis, with bubbles produced on the y-axis.
- Label the axes with units: carbon dioxide concentration / mg per dm on the x-axis, and number of bubbles produced in 5 minutes on the y-axis.✓
- Use an even linear scale so the plotted points fill half or more of the grid in both directions, for example 0 to 12 mg per dm across and 0 to 40 bubbles up.✓
- Plot all six points accurately, to within half a small square: (2, 4), (4, 14), (6, 20), (8, 25), (10, 35), (12, 35).✓
- Join the points with ruled straight lines, without extending the line beyond the first and last points (a line of best fit is also accepted).✓
AnswerLabelled axes with units; scale filling half the grid in both directions; all six points plotted accurately; ruled line joining the points with no extrapolation
Read the direction of the line as the independent variable increases.
- As the carbon dioxide concentration increases, the number of bubbles increases, and then levels off between 10 and 12 mg per dm.✓
AnswerAs carbon dioxide concentration increases, the number of bubbles increases (and then levels off)
The table gives bubbles per 5 minutes, so divide by 5 to get bubbles per minute, then round to one significant figure.
- At 4 mg per dm the table shows 14 bubbles in 5 minutes.✓
- Round to one significant figure: bubbles per minute.✓
Answer bubbles per minute
The independent variable is the one the student deliberately changed.
- The student set up five different concentrations of carbon dioxide in the water, so this is the variable changed.✓
AnswerCarbon dioxide concentration
Change light intensity (for example the lamp distance), collect the gas in a way that gives a volume, and control the other factors.
- Independent variable: use at least two different light intensities, for example by placing the lamp at 10, 20 and 30 cm from the plant.✓
- Set up the lamp and the aquatic plant in water, as in the given method, and use a ruler to measure the distance from the lamp to the plant.✓
- Put a heat shield (such as a beaker of water) between the lamp and the plant, and leave the plant for a few minutes at each new distance to equilibrate before taking readings.✓
- Collect the gas in a gas syringe or an inverted measuring cylinder (a photosynthometer), and measure the volume of gas produced in a set time, for example 5 minutes, or the time taken to produce a set volume.✓
- Control other variables: keep the temperature, the plant species and size (number of leaves), the carbon dioxide concentration and the volume of water the same for every light intensity.✓
- For safety, keep the electric lamp away from the water, and repeat the whole investigation at least two more times so the results are reliable.✓
AnswerAt least two light intensities (lamp distance measured with a ruler, heat shield, equilibration time); gas collected in a gas syringe or measuring cylinder and volume measured in a set time; controlled variables; safety precaution; repeats
Also listed as0610/53/M/J/21 · 0610/53 M/J 21 · 0610_s21_qp_53 · 0610_s21_ms_53 · 0610 s21 qp 53 · 0610 May/June 2021 Paper 53