Cambridge IGCSE · 0610/61/O/N/20
IGCSE Biology 0610/61 October/November 2020
- 1 hour
- 40 marks
- Variant 1
At a glance
2 questions, 40 marks, across 2 topics. Most marks: Human nutrition (22 marks, 55%) and Reproduction (18 marks, 45%).
Practise by topic
Pick a topic for more questions like it.
Question by question
2 questions · 40 marks
- Q1Human nutrition, Biological molecules, Enzymes22 marks
- Q2Reproduction18 marks
Worked answers
Step-by-step solutions, with the mark-scheme points each step earns.
Q1Human nutrition, Biological molecules, Enzymes22 marks
The concentration is the 2% stock diluted by the fraction of the total volume that is lipase solution.
- Test-tube L3 has lipase in a total of , which is one quarter.
- Concentration , continuing the halving pattern 2.0, 1.0, 0.5.✓
Answer
Draw a headed table with units, then convert each stopwatch reading from minutes and seconds into seconds.
- Draw a table with at least two columns and a header line, with a column for the percentage concentration of lipase and a column for the time.✓
- Give the column headings units, for example "concentration of lipase / %" and "time / s".✓
- Convert the times to seconds: L1 is , L2 is , L3 is , and L4 shows no change at 5 minutes, recorded as .✓
AnswerTable of lipase concentration (2.0, 1.0, 0.5, 0.0 %) against time / s: 25, 38, 77, >300.
Watch outWriting L3 as 1.17 or 117 instead of converting 1 minute 17 seconds to 77 seconds.
Link the lipase concentration to the time for the indicator to change colour.
- As the lipase concentration increases, the time taken for the indicator to change colour decreases, so the fat in the milk is broken down faster.✓
AnswerAs the lipase concentration increases, the time taken for the colour to change decreases (the higher the concentration, the faster the fat is broken down).
A control is the set-up with no enzyme, used as a comparison to show that the enzyme causes the change.
- Control: test-tube L4, which contains distilled water and lipase.✓
- Explanation: it shows that the lipase (enzyme) is what causes the colour change of the indicator, because without lipase there was no change.✓
AnswerControl: L4 (distilled water, 0% lipase). It shows that lipase is causing the change in colour of the indicator.
Use Table 1.1 to turn each final colour into a pH value.
- L1 turned yellow, which is in Table 1.1. L4 stayed blue, which is .✓
AnswerL1 and L4
The independent variable is what the student deliberately varied between test-tubes.
- The student changed the concentration of lipase (enzyme) by diluting it with different volumes of water.✓
AnswerConcentration of lipase (enzyme)
Anything else that could change the speed of the colour change must stay the same in every test-tube.
- Keep the volume of milk the same ().✓
- Keep the volume of sodium carbonate solution the same (also acceptable: the total volume of enzyme solution, or the number of drops of bromothymol blue).✓
AnswerAny two of: volume of milk, total volume of enzyme solution, volume of sodium carbonate solution, number of drops of indicator.
Enzyme reactions depend on temperature, so everything should be at the same temperature before the reaction starts.
- Leaving the test-tubes in the water-bath gives their contents enough time to reach the temperature of the water-bath (to equilibrate) before they are mixed.✓
AnswerTo give the contents time to reach the temperature of the water-bath before mixing.
Look at how the end-point is judged in step 8.
- The colour change is judged by eye, so it is subjective and the end-point is hard to decide exactly.✓
AnswerJudging the colour change by eye is subjective, and the end-point is hard to judge.
Lipase is an enzyme and so a protein, and proteins are detected with biuret reagent.
- Method: add biuret reagent (solution) to the lipase solution.✓
- Positive result: the colour changes from blue to purple (lilac, violet or mauve).✓
- Safety precaution: wear gloves, safety glasses or goggles.✓
AnswerAdd biuret reagent; positive result is a change from blue to purple (lilac, violet, mauve); wear gloves or goggles.
Test lipase at several temperatures including 37 degrees Celsius, keep everything else constant, and compare the time for the indicator to change colour.
- Use at least three temperatures, with one below , one at and one above it, for example , and .✓✓
- Maintain each temperature with a water-bath (checked with a thermometer), and equilibrate the lipase and milk mixtures at that temperature before mixing.✓
- Using the given method, add the same volume of milk, the same volume of sodium carbonate and the same number of drops of indicator to each tube, then measure the time taken for the indicator to change colour.✓
- Keep other variables constant, for example the volume and concentration of lipase, the type of milk or fat, and the volume of fat.✓
- Repeat at least twice at each temperature, and conclude that the optimum is the temperature with the shortest time.✓
AnswerTest at three or more temperatures (below, at and above 37 degrees Celsius) held in water-baths, time the colour change, keep other variables constant and repeat.
Q2Reproduction18 marks
Match each labelled part in the photograph (Fig. 2.2) to the labelled diagram (Fig. 2.1), then count how many of that part are visible.
- A is the stigma at the top of the carpel, the tip of the long style. Only one is visible.✓
- B is a filament, the thin stalk that carries an anther, as part of a stamen. Eight are visible.✓
- C is a sepal, the small outer leaf-like part at the base of the flower. Four are visible.✓
AnswerA: stigma, 1. B: filament, 8. C: sepal, 4.
A good biological drawing is large, uses a clear single line, shows the structures you can see inside, and is labelled with a ruled line.
- Use a clear single outer line without shading.✓
- Make the drawing large, so that the line X to Y is longer than .✓
- Draw the rounded structures inside the grain.✓
- Draw the top edge of the pollen tube with one indentation.✓
- Label the pollen tube with a ruled label line that touches it.✓
AnswerA large unshaded single-line outline (XY over 35 mm) with rounded structures inside the grain, an indented pollen tube top edge, and the pollen tube labelled.
Rearrange the magnification equation to actual length = measured length divided by magnification.
- Measure the line XY on Fig. 2.3: (accepted range ).✓
- Rearrange: actual length .
- Substitute, using the magnification of : actual length .✓
- Give the unit, which is the same as the unit you measured in: (equivalent to or ).✓
Answer (, )
Watch outLeaving out the unit, or multiplying the measurement by 350 instead of dividing.
Compare the two rows of Table 2.2 over time, looking at the start, the end, and where each levels off.
- Pollen germinated faster in S1 than in S2 at the start, for example against at 20 minutes.✓
- By 60 minutes there was no difference in percentage germination between S1 and S2, because both reached .✓
AnswerAny two of: germination faster in S1 than S2 at the start; no difference between S1 and S2 by 60 minutes; S1 stops germinating after 50 minutes; only 51% of grains germinated.
The slides did not hold the same number of pollen grains, so raw counts are not directly comparable.
- Slide one had 210 pollen grains and slide two had 250, so different numbers of grains were counted on each slide. Percentages remove the effect of this difference.✓
AnswerDifferent numbers of pollen grains were counted on each slide, so percentages allow a fair comparison.
A percentage is a part divided by the whole, times 100.
- Divide the number of pollen grains that had germinated by the total number of pollen grains on the slide.✓
- Multiply the result by 100.✓
AnswerNumber germinated divided by total number of pollen grains, multiplied by 100.
Choose an even y-axis scale so the tallest value, , fits on the grid, then draw bars that match the table.
- Add a y-axis scale with even, suitable numbers that fit the bar for A at and the tallest bar of , for example 0 to 300 in steps of 50.✓
- Plot bars for B at and C at with the same width as A, and label each bar B and C.✓
AnswerEvenly scaled y-axis with suitable numbers (bar A at 190); bars B at 220 and C at 265, correct and labelled.
Also listed as0610/61/O/N/20 · 0610/61 O/N 20 · 0610_w20_qp_61 · 0610_w20_ms_61 · 0610 w20 qp 61 · 0610 October/November 2020 Paper 61