Cambridge IGCSE · 0610/62/M/J/20
IGCSE Biology 0610/62 May/June 2020
- 1 hour
- 40 marks
- Variant 2
At a glance
2 questions, 40 marks, across 1 topic. Most marks: Movement into and out of cells (40 marks, 100%).
Practise by topic
Pick a topic for more questions like it.
Question by question
2 questions · 40 marks
Worked answers
Step-by-step solutions, with the mark-scheme points each step earns.
Q1Movement into and out of cells, Biological molecules, Movement in and out of cells18 marks
Read both thermometers, convert minutes to seconds, and record the results in a table with units.
- Draw a table with at least two columns and a header row, with one row for test-tube C and one for H.✓
- Head the columns temperature / and time taken / s.✓
- Record the temperatures read from Fig. 1.3, 18 for C and 78 for H, and the converted times: C s; H s.✓
AnswerC: 18 , 516 s; H: 78 , 83 s, in a table with headed columns.
Compare the times: the hot tube lost the cross much faster than the cold tube.
- The cross disappeared after 83 s at but after 516 s at , so diffusion is faster at higher temperatures.B1
AnswerAt higher temperatures the iodine solution diffuses faster, so the cross disappears more quickly.
The independent variable is the factor the student deliberately changed between the tubes.
- The student used cold water in C and hot water in H, so the variable changed was the temperature (of the water).B1
AnswerTemperature (of the water)
Starch gives a blue-black colour with iodine, so the colour of the liquid outside shows whether starch has crossed.
- Conclusion: starch molecules do not pass through the dialysis tubing.✓
- Evidence: the liquid around the bag stayed brown and did not turn blue-black.✓
AnswerStarch does not pass through the dialysis tubing; the liquid around the bag remained brown.
Name an error that affects the timings and match it to apparatus that would reduce it.
- Error: the temperature of the water was not controlled, so it changed during the investigation.✓
- Apparatus: a thermostatically controlled water-bath keeps the temperature constant (insulation or a Bunsen burner also work).✓
AnswerError: temperature of the water not controlled. Apparatus: thermostatically controlled water-bath.
Watch outGiving apparatus that does not fix the error named, for example a measuring cylinder for the temperature error.
Reducing sugars are detected with Benedict's reagent, which needs heating to change colour.
- Method: add Benedict's solution to a sample of the solution being tested.✓
- Heat the mixture (in a hot water-bath).✓
- Result: a positive test turns the blue mixture green, yellow, orange or red.✓
AnswerAdd Benedict's reagent and heat; a positive result is a colour change to green, yellow, orange or red.
A plan states the independent variable (amylase concentration), the dependent variable, constant variables, repeats and safety.
- Method: at set time intervals, use Benedict's reagent to measure the reducing sugar produced, or spot samples onto a tile with iodine solution to find the starch remaining.✓
- Use a thermostatically controlled water-bath to keep every tube at the same temperature.✓
- Independent variable: use at least two different concentrations of amylase.✓
- Keep constant: the same type of enzyme and the same concentration of starch suspension.✓
- Keep constant: the same temperature, the same pH and the same incubation time for the enzyme and starch.✓
- Dependent variable: record the amount of reducing sugar produced, or the time for the iodine drops to stay brown.✓
- Repeat at least twice more, and wear eye protection and gloves when heating or handling the reagents.✓
AnswerUse at least two amylase concentrations; keep starch concentration, temperature, pH and time constant; measure sugar produced or time for starch to disappear; repeat; state a safety precaution.
Q2Movement into and out of cells, Gas exchange in humans, Movement in and out of cells22 marks
A fair test changes only the sugar concentration, so everything else that could alter the potato's mass must be held the same.
- Keep the temperature the same for all six sticks.✓
- Keep the size of the potato sticks (length, shape, surface area) and the volume of sugar solution the same, and use the same variety of potato; any two of these score.✓
AnswerAny two from: temperature; length / size / shape / surface area of the potato stick; volume of sugar solution; variety of potato.
The dependent variable is what the student measures at the end to see the effect.
- The student weighed each stick before and after, so the measured quantity is the mass of the potato stick.B1
Answer(Initial / final) mass of the potato stick
Percentage change is the change in mass divided by the initial mass, multiplied by 100.
- Change in mass = final initial .
- Percentage change:B2
Answer
A line graph needs correctly labelled axes, a sensible scale, accurately plotted points and a line joining them.
- Put concentration of sugar solution / on the x-axis and percentage change in mass on the y-axis, both labelled with units.✓
- Use an even scale with positive and negative values on the y-axis (the zero line is already marked), so the plot fills at least half the grid.✓
- Plot the six points , , , , and to within half a small square.✓
- Join the points with a ruled line or a smooth best-fit line that falls as concentration rises.✓
AnswerLabelled axes with units, even scale filling half the grid, all points plotted within half a small square, and a line joining the points.
No change in mass means the line crosses the zero line, so read the concentration at that point.
- The line crosses 0% change between 0.2 and 0.4 mol per dm; interpolating between and gives about .B1
AnswerThe concentration read from your graph where it crosses 0% change (about ).
To pin down the crossing point, test more closely spaced concentrations where the sign of the change flips.
- Use concentrations at smaller intervals.✓
- Choose them between 0.2 and 0.4 mol per dm, since the mass change switches from gain to loss in that range.✓
AnswerRepeat using concentrations at smaller intervals between 0.2 and 0.4 mol per dm.
A good biological drawing has clean single lines, fills the space, and copies the cell's shape and contents accurately.
- Draw clear single lines with no shading.✓
- Make the drawing large, occupying at least half of the space available.✓
- Draw the cell wall as a pentagon-shaped outline of cell X, matching its shape.✓
- Include the starch grains inside, about 7 to 9, with their relative sizes copied from the photograph.✓
AnswerA large, unshaded, single-line drawing of the pentagon-shaped cell X containing 7 to 9 starch grains of the correct relative sizes.
Measure PQ in millimetres with a ruler, then divide by the actual length, using the same units.
- Measure line PQ on the figure: .✓
- Magnification:✓
- To the nearest whole number the magnification is . Measuring PQ as 44 or 46 mm gives , or , which are also accepted.✓
AnswerLength of PQ ; magnification (314, 328 or 329 also accepted).
The average is the total of the five lengths divided by five.
- Add: .
- Divide by 5:B1
Answer
Carbon dioxide is detected with hydrogencarbonate indicator (or limewater): name the test, then give its positive result.
- Indicator: hydrogencarbonate indicator.✓
- Result: it turns yellow when carbon dioxide is present. (Limewater turning cloudy or milky is the alternative test.)✓
AnswerHydrogencarbonate indicator turns yellow; or limewater turns cloudy / milky.
Also listed as0610/62/M/J/20 · 0610/62 M/J 20 · 0610_s20_qp_62 · 0610_s20_ms_62 · 0610 s20 qp 62 · 0610 May/June 2020 Paper 62