Cambridge IGCSE · 0610/61/M/J/19

IGCSE Biology 0610/61 May/June 2019

  • 1 hour
  • 40 marks
  • Variant 1
/ …
View
Loading original PDF…

At a glance

2 questions, 40 marks, across 2 topics. Most marks: Plant nutrition (21 marks, 53%) and Movement into and out of cells (19 marks, 48%).

Practise by topic

Pick a topic for more questions like it.

Question by question

2 questions · 40 marks

  1. Q1Movement into and out of cells, Movement in and out of cells19 marks
  2. Q2Plant nutrition, Organisation of the organism21 marks

Worked answers

Step-by-step solutions, with the mark-scheme points each step earns.

Q1Movement into and out of cells, Movement in and out of cells19 marks
(a)(i)3 marks

The table needs a column for the concentration and a column for the distance, with units, and a row for each of A, B and C.

  1. Draw a table with at least two columns and a line separating the headings from the data.
    ✓
  2. Write the headings with their units: 'percentage concentration of citric acid solution (%)' and 'distance travelled / mm' (or cm).
    ✓
  3. Enter the three concentrations (0.5, 1.0 and 5.0). For each section, measure with a ruler from the edge of the hole to the edge of the coloured ring, and record each distance in mm to the same precision. The distances increase from A to B to C.
    ✓

AnswerA table with headings and units (concentration %, distance / mm) and three correct distances, increasing from A to C

(a)(ii)1 mark

The acid spreads out from the hole in a circle, so measure from the hole to the edge of the coloured circle, or measure across the circle.

  1. Measure from the edge of the hole to the edge of the red (or yellow) circle. Measuring the diameter or radius of the red (or yellow) circle is also accepted.
    ✓

AnswerFrom the edge of the hole to the edge of the red / yellow circle (or the diameter / radius of the circle)

(a)(iii)1 mark

Compare concentration with distance across the three sections of the dish.

  1. The higher the concentration of the citric acid solution, the further the acid moved through the agar.
    ✓

AnswerThe higher the concentration, the further the acid moves

(a)(iv)2 marks

Substitute into the formula: square the distance, then divide by the time.

  1. Substitute the distance of 14 mm14\text{ mm} and the time of 30 minutes30\text{ minutes}:
    14230=19630=6.533…\frac{14^2}{30} = \frac{196}{30} = 6.533\ldots
  2. Round to two significant figures: 6.5 mm26.5\text{ mm}^2 per minute.
    ✓✓

Answer6.5 mm26.5\text{ mm}^2 per minute

Watch outForgetting to square the distance, which gives 14÷30=0.4714 \div 30 = 0.47.

(a)(v)2 marks

Universal Indicator is green at neutral pH and red in strong acid.

  1. Green agar is neutral: pH 7.
    ✓
  2. Red agar is strongly acidic: pH 1 or 2.
    ✓

AnswerGreen agar pH 7; red agar pH 1 or 2

(b)(i)2 marks

A constant is anything the student kept the same for all three solutions, apart from concentration.

  1. Any two of: the number of drops of solution (three), the agar or its depth, the size of the holes, the type of indicator, the time (30 minutes), the temperature.
    ✓✓

AnswerTwo from: three drops; same agar / depth; hole size; same indicator; 30 minutes; temperature

(b)(ii)2 marks

Give an error and a matching effect on the results; the effect must follow from the error.

  1. Error: the drop sizes varied between the solutions.
    ✓
  2. Effect: a larger volume would produce a greater diffusion distance.
    ✓

AnswerError: drop sizes vary. Effect: a larger volume gives a greater diffusion distance. (Other pairs: no repeats, so anomalous results cannot be identified; one pipette used for all solutions, so contamination makes a weaker solution travel less far.)

(c)6 marks

Keep the agar plate method (holes, indicator, acid, fixed time, measure distance) but make temperature the changed variable, kept below 70 degrees C so the agar does not melt.

  1. Use agar plates containing Universal Indicator, with holes cut in the agar.
    ✓
  2. Add the same concentration of citric acid to each hole, leave for a fixed time, and measure the distance moved by the colour change.
    ✓
  3. Use a range of at least two temperatures, all below 70∘C70^\circ\text{C}, for example 20∘C20^\circ\text{C}, 40∘C40^\circ\text{C} and 60∘C60^\circ\text{C}.
    ✓
  4. Keep each plate at its temperature, for example in a water bath or incubator.
    ✓
  5. Leave the plates to reach each temperature before adding the acid.
    ✓
  6. Repeat at least twice (or use three holes in each plate) and wear gloves and goggles.
    ✓

AnswerAgar plates with indicator and holes, same acid concentration, fixed time, measure distance at several temperatures below 70 degrees C, equilibrated and held constant, with repeats and safety.

Q2Plant nutrition, Organisation of the organism21 marks
(a)(i)3 marks

A plan diagram shows only the layers of tissue as outlines, so draw it big, with plain lines, and keep each layer's thickness in proportion to the photograph.

  1. Use a sharp pencil and draw clear, single, continuous lines for each layer boundary, with no shading and no individual cells.
    ✓
  2. Make the drawing large, filling at least half of the space available.
    ✓
  3. Draw the layers in the same proportions as the photograph: thin upper epidermis, then the palisade layer, then the thicker spongy mesophyll with air spaces, then the thin lower epidermis.
    ✓

AnswerA large plan diagram with clean single lines, no cells drawn, and layers in correct proportion: upper epidermis, palisade, spongy mesophyll, lower epidermis.

Watch outShading the layers or drawing individual cells, which the question forbids.

(a)(ii)3 marks

Measure AB with a ruler in mm, then rearrange the magnification formula to find the actual thickness.

  1. Measure line AB on Fig. 2.1 with a ruler: AB=40 mmAB = 40\text{ mm}.
    ✓
  2. Rearrange the formula:
    actual thickness=length of ABmagnification\text{actual thickness} = \frac{\text{length of AB}}{\text{magnification}}
  3. Substitute the measurement and the magnification of ×100\times 100, keeping the units:
    40 mm100=0.4 mm\frac{40\text{ mm}}{100} = 0.4\text{ mm}
    ✓✓

AnswerActual thickness =0.4 mm= 0.4\text{ mm} (from AB=40 mmAB = 40\text{ mm})

Watch outLeaving out the unit, or multiplying by 100 instead of dividing.

(a)(iii)1 mark

Fig. 2.2 shows rounded, loosely packed cells with chloroplasts and air gaps between them, which is spongy mesophyll.

  1. Write X on the spongy mesophyll layer of your drawing, the thick layer of loosely arranged cells with air spaces between the palisade layer and the lower epidermis.
    ✓

AnswerX written on the spongy mesophyll layer

(b)(i)1 mark

Leaves vary naturally, so more leaves give a more reliable average.

  1. A large sample gives a representative leaf size, because the average is not distorted by a few unusual leaves, and it helps identify anomalous results.
    ✓

AnswerTo obtain a representative leaf size / to identify anomalous results

(b)(ii)1 mark

Random choice stops the scientists picking leaves that favour a result.

  1. Random selection avoids bias and gives a representative sample, so the leaves from the different light intensities can be fairly compared.
    ✓

AnswerTo avoid bias and gain a representative sample, so a fair comparison can be made

(b)(iii)2 marks

Surface area is found by covering the leaf with the grid and counting the squares it occupies.

  1. Draw round the outline of the leaf on the millimetre grid, or place the leaf under a transparent grid.
    ✓
  2. Count the squares inside the outline, including any square more than half covered, to give the area in mm2\text{mm}^2.
    ✓

AnswerPlace the leaf on or under the grid, outline it, count squares (counting those more than half covered) to get area in mm2\text{mm}^2

(b)(iv)1 mark

The independent variable is the one the scientists deliberately changed.

  1. The plants were grown in three different light intensities, with soil and watering kept the same, so the variable changed is light intensity.
    ✓

AnswerLight intensity

(c)(i)2 marks

Percentage difference is the change divided by the starting value (50 units) multiplied by 100.

  1. Find the change in area for species A from 50 to 10 units:
    6500−3900=2600 mm26500 - 3900 = 2600\text{ mm}^2
  2. Divide by the value at 50 units, multiply by 100 and round to the nearest whole number:
    26003900×100=66.7…≈67%\frac{2600}{3900} \times 100 = 66.7\ldots \approx 67\%
    ✓✓

Answer67%67\%

Watch outDividing by 6500 instead of 3900, which gives 40%.

(c)(ii)4 marks

Plot a grouped bar chart with light intensity on the x-axis, leaf area on the y-axis, and A and B side by side at each intensity.

  1. Label the x-axis 'light intensity / arbitrary units' and the y-axis 'average leaf area / mm2\text{mm}^2', and give a key (or labels) for species A and B.
    ✓
  2. Use an even scale for leaf area (for example 1000 mm2\text{mm}^2 per big square) and a sequential x-axis (10, 50, 100). The bars must fill at least half the grid in both directions.
    ✓
  3. Plot all six values accurately to within half a small square: A 3600, 3900, 6500 and B 2800, 3400, 2900 at 100, 50 and 10 units.
    ✓
  4. Draw bars of equal width (at least one small square wide), with gaps between the pairs of bars.
    ✓

AnswerGrouped bar chart with labelled axes with units and a key, even scale filling over half the grid, six values plotted accurately, equal-width bars with gaps between pairs.

(c)(iii)2 marks

Describe each species' trend separately, quoting the direction of change as light intensity changes.

  1. Species A: as light intensity decreases, average leaf area increases (it is largest at 10 units).
    ✓
  2. Species B: average leaf area increases as light intensity increases up to a maximum at 50 units, and then decreases.
    ✓

AnswerA: leaf area increases as light intensity decreases. B: leaf area rises to a maximum at 50 au, then falls.

(c)(iv)1 mark

The peak for B is at 50 units, but only three intensities were tested, so test more values close to it.

  1. Measure leaf growth at a narrower range of light intensities around 50 arbitrary units, for example 30, 40, 50, 60 and 70.
    ✓

AnswerMeasure leaf growth at a narrower range of light intensities around 50 au

Also listed as0610/61/M/J/19 · 0610/61 M/J 19 · 0610_s19_qp_61 · 0610_s19_ms_61 · 0610 s19 qp 61 · 0610 May/June 2019 Paper 61